ST-TC1 | TELEPHONE SYSTEM COUPLER - CO LINE SIMULATOR
Item # ST-TC1
TELEPHONE SYSTEM COUPLER - CO LINE SIMULATOR
The ST-TC1 is intended to be connected to an on-site telephone system switching unit KSU. It is NOT intended to be connected directly to a telephone CO line. Connections from the ST-TC1 go into the telephone switching unit as if the ST-TC1 was an incoming phone line.
When the KSU seizes the line to the ST-TC1, a relay contact closure is provided which can be used to control a variety of equipment, such as a paging system or radio system. The closure is maintained as long as the line is seized. A 600 Ω transformer-isolated audio feed is available for audio input to or output from the telephone switching unit. The ST-TC1 will pass DTMF audio from a telephone keypad or other DTMF generating device.
The ST-TC1 may be utilized to add paging zones or radio system interface to a telephone system. When any instrument in the telephone system seizes the line associated with the ST-TC1, the relay closes to activate the radio or paging function, and the audio spoken into the handset is broadcast. The ST-TC1 can not be connected to a phone line that has ringer voltage present.
The ST-TC1 can be used in conjunction with RDL''s ST-VOX1 modules to provide two-way communication. The ST-VOX1 will provide the necessary push-to-talk function to key the two-way communications systems.
Features:
- Simulate a Telco CO Line
- Connect to local telephone switch or instrument
- Add Radio Control or Paging to KSU
- Contact Closure when Line is Off-hook
- Audio Input/Output from Telephone Switching Unit
| Mic Input | 5 kΩ unbalanced line |
|---|---|
| Line Input | 200 kΩ unbalanced |
| Control Outputs | Open-Collector @ 25 mA, suitable to drive indicators or Slave LCR |
| Relay Contacts | Double-pole-double-throw |
| Max. Switching Power | 60 W, (220 Vdc, 125 Vac, 2A) |
| Mic Input Sensitivity | Adjustable -80 dBu to -50 dBu |
| Line Input Sensitivity | Adjustable -45 dBu to -15 dBu |
| Indicators | Audio threshold LED (for setting sensitivity) |
| Retrigger Delay | 50 ms |
| Release Delay Time Adjustment Range | Relay Contacts: 70 to 260 msSlave open-collector output: 15 to 260 ms |
| Activation Response Time | Relay Contacts: 5 msSlave open-collector output: 3 ms |
| Ambient Operating Environment | 0° C to 55° C |
| Power Requirement | GROUND-REFERENCED 24 Vdc @ 50 mA ** Assumes 20 mA max load at SLAVEoutput |
| Dimensions | Height: 0.7 in. (1.7 cm), Width: 3 in. (7.6cm), Depth 1.6 in. (3.9 cm) |
| Package Type | Cardboard Box |
| WEEE weight | 0.15 lbs. |
| Shipping Weight | 0.2 lbs. |
| Tariff code | 8543.70.9860 |
| Package Dimensions | 2 x 2 x 4 in. |
Downloads