Item # ELITE-20 PF I
CONDITIONER POWER HIGH TENSION 20 AMP POWER FACTOR
Item # ELITE-20 PF I
CONDITIONER POWER HIGH TENSION 20 AMP POWER FACTOR
- UM: EA
- Estimated Weight: 23.0
- Brand: FURMAN
The extreme AC demands encountered in the professional audio / video arena have required technological developments far in excess of typical home theater/audiophile power products. In studios, live sound, and broadcast facilities, breakdown is unacceptable. Equipment failure or poor performance is costly. The same is true of today’s home theater. Our solution based technology, extensive engineering expertise, and robust build quality have answered the challenge of today’s corrupted power lines, and led to the creation of the Elite-20 PF i.
The Elite-20 PF i is so substantial in its ability to unmask critical signal content, its performance is surpassed only by the Furman Reference Series. With Furman’s Ultra-Linear Filtering, televisions, projectors, DVD players, amplifiers, and processors, are fed pristine AC power.
The Elite-20 PF i also features remote control capability via 12V triggering, compatible with the 12V triggering devices commonly found in power receivers and pre-amp processors. Additional products (such as a remote subwoofer) can be daisy-chained from the 12V output jack for an additional triggered unit. The 12V triggering feature may be bypassed if desired.
For the first time, low-level analog, digital, and video components are not modulated or distorted by the power amplifier’s extreme AC current demands. Further, the power amplifier is fed a highly filtered, extremely low-impedance supply of AC power. The Elite-20 PF i, in fact, has in excess of 4 Amps of continuous current reserve (over 55 amps peak charge) for the most extreme peak power demands. This technology enables power amplifiers and powered subwoofers to operate at maximum efficiency, reaching levels of performance previously unattainable.
The net effect is as if your power amplifier virtually doubled in power and improved immeasurably in quality.
Features
SMP provides the highest level of protection available
LiFT significantly reduces AC line noise
E.V.S. protects equipment from dangerous overvoltage conditions
Zero ground contamination circuitry protects critical digital components
Power Factor Technology provides over 55 Amps peak charge surplus current for power-starved amplifiers
Ultrasonic bi-filtering isolates digital and video circuits from analog components
Retractable LED lamps illuminate a cabinet or rack full of equipment
Detachable module for telco surge suppression and 3 pairs of cable / satellite TVSS isolated F-connectors
12 Volt triggering for remote control
General |
|
Family |
Elite Series |
Line Voltage |
120 (Volts) |
Number of Outlets |
13 |
Number of Isolated Banks |
3 |
Outlet Descriptions |
1 (Ultra-Linearly filtered outlet – front panel), 8 (Ultra-Linearly filtered outlets with additional ultrasonic filtering for either video or audio components, 4 with 12V triggering), 4 (Power Factor Technology amplifier outlets – 4.5 amps RMS reserve – reactive load – over 55 amps peak charge, 2 with 5 second delay via 12V triggering) |
Rack Mountable |
Yes |
Rack Ears Included |
Yes |
Front Panel Meter(s) |
No |
Front Media Light(s) |
2 Retractable LED lamps |
Control |
On/Off switch and light dimmer knob on front panel. 12 Volt triggering for remote control. |
Voltage Regulation |
No |
Compliance |
NRTL-C |
USB Charging |
N/A |
Low Voltage Trigger |
12 V, In/Out |
Dimensions |
4" H x 17" W x 14.75" D (Standard 2 RU height without feet) |
Weight |
18 lbs |
Power Consumption |
12 Watts for display and control circuits independent of actual load |
AC Protection |
|
AC Protection Technology |
Extreme Voltage Shutdown, Series Multi-Stage Protection, Non-sacrificial protection with zero ground contamination |
Under-Voltage Shutoff |
85V |
Over-Voltage Shutoff |
140V ±3V |
Maximum Current Rating |
20 (Amps) |
Initial Clamping Level |
188 VAC peak @ 3,000 Amps |
Filtration |
|
Filtration Technology |
LiFT |
Filtration Rating |
Transverse (Differential) Mode:> 40 dB from 5Khz. – 100 kHz.>80 dB from – 100 kHz. – 1GHz. Common Mode:>40dB from 10Hz. – 30 kHz.>20 from 40 kHz. – 1MHz.(Linear attenuation curve from 0.05 – 100 ohms line impedance) |
Signal Line Protection1 Tel |
3 Cable/Satellite |