With Furman’s exclusive Linear Filtering Technology, televisions, projectors, DVD players, amplifiers, and processors, are fed by linearly filtered AC power. This dramatically reduces noise, ensuring consistent peak operation regardless of load conditions or the time of day.
Another critical feature is our exclusive Series Multi-Stage Protection. This virtually maintenance-free surge suppression assures the highest level of AC protection possible, without sacrificing itself when the offending surge is severe — no damaged equipment, no service calls, no down time. Further, our famous retractable front panel LED lamps allow easy viewing of either a rack or cabinet full of equipment, even when your theater lights are off.
The Elite-15 PF i also features remote control capability via 12V triggering, compatible with the 12V triggering devices commonly found in power receivers and pre-amp processors. Additional products (such as a remote subwoofer) can be daisy-chained from the 12V output jack for an additional triggered unit. The 12V triggering feature may be bypassed if desired.
At the center of the Elite-15 PF i is our unique Power Factor Technology. For the first time, low-level analog, digital, and video components are not modulated or distorted via the power amplifier’s extreme AC current demands. Further, the power amplifier sees a highly filtered, extremely low-impedance supply of AC power. The Elite-15 PF i, in fact, has in excess of 3 Amps of continuous current reserve (over 45 amps peak charge) for the most extreme peak power demands. This technology enables power amplifiers and powered subwoofers to operate at peak efficiency.
Features
SMP provides the highest level of protection available
LiFT significantly reduces AC line noise
E.V.S. protects equipment from dangerous overvoltage conditions
Zero ground contamination circuitry protects critical digital components
Power Factor Technology provides over 45 amps peak charge surplus current for power-starved amplifiers
Retractable LED lamps illuminate a cabinet or rack full of equipment
12 volt triggering for remote control
General |
|
Family |
Elite Series |
Line Voltage |
120 (Volts) |
Number of Outlets |
13 |
Number of Isolated Banks |
3 |
Outlet Descriptions |
1 (linearly filtered outlet, front panel), 4 (linearly filtered audio-video outlets, 2 switched via 12V trigger), 4 (linearly filtered outlets with additional ultrasonic filtering for video components, 2 switched via 12 V trigger), 4 (Power Factor Technology amplifier outlets, 3 amps RMS reserve, reactive load, over 45 amps peak charge, 2 switched with 5 second delay via 12V trigger) |
Rack Mountable |
Yes |
Rack Ears Included |
Yes |
Front Panel Meter(s) |
No |
Front Media Light(s) |
2 Retractable LED lamps |
Control |
On/Off switch and light dimmer knob on front panel. 12 Volt triggering for remote control. |
Voltage Regulation |
No |
Compliance |
NRTL-C |
USB Charging |
N/A |
Low Voltage Trigger |
12 V, In/Out |
Dimensions |
4” H x 17” W x 14.75” D (Standard 2 RU height without feet) |
Weight |
15 lbs |
Power Consumption |
12 Watts for display and control circuits independent of actual load |
AC Protection |
|
AC Protection Technology |
Extreme Voltage Shutdown, Series Multi-Stage Protection, Non-sacrificial protection with zero ground contamination |
Under-Voltage Shutoff |
85V |
Over-Voltage Shutoff |
140V ±3V |
Maximum Current Rating |
15 (Amps) |
Initial Clamping Level |
188 VAC peak @ 3,000 Amps |
Filtration |
|
Filtration Technology |
LiFT |
Filtration Rating |
>40 dB from 10Khz. – 100 kHz. >80 dB from 100 Khz. _ 1GHz.(Linear attenuation curve from 0.05 _ 100 ohms line impedance) |
Signal Line Protection |
1 Tel, 3 Cable/Satellite |